Power Cables
Heat & Cold resistant Spezial Heat Resistant Impregnation halogen free HELUTHERM 400
Number Of Cores(Core) | 3 | Finished outer diameter(mm) | 8.3 | Sheath (outer coating) color | Gray |
---|---|---|---|---|---|
Core insulation | Glass silk wrapping, silicone impregnated | Coat Material | Glass silk wrapping, silicone impregnated | Conductor Nominal cross-section | 1.5 |
Rated voltage U(kV) | 0.5 | Conductor class | fine wired | Stranding | Core |
Core identification | colored | protective conductor | no | Halogen-free according to EN 50267-2-3 | yes |
oil resistance | no |
Heat & Cold resistant Spezial Heat Resistant Impregnation screened halogen free HELUTHERM 400 ES
Sheath (outer coating) color | Gray | Core insulation | Glass silk wrapping, silicone impregnated | Coat Material | Glass silk wrapping, silicone impregnated |
---|---|---|---|---|---|
Rated voltage U(kV) | 0.5 | Conductor class | fine wired | Stranding | Core |
Core identification | colored | protective conductor | no | Halogen-free according to EN 50267-2-3 | yes |
oil resistance | no |
Heat & Cold resistant UV resistant halogen free HELUTHERM 145 MULTI
Sheath (outer coating) color | Black | Core insulation | Polyolefin copolymere | Coat Material | Polyolefin copolymere |
---|---|---|---|---|---|
Conductor class | fine wired | Stranding | Core | Halogen-free according to EN 50267-2-3 | no |
oil resistance | no |
Installation Cable PVC NYM
Rated voltage U(kV) | 0.5 | Rated voltage Uo(kV) | 0.3 | Perm. External cable temperature during installation / handling | +5°C to +70°C |
---|---|---|---|---|---|
Perm. External cable temperature after mounting without vibration | -40°C to +70°C | Test voltage(kV) | 2.0 |
KOAX RG 11 A/U
Finished outer diameter(mm) | 10.3 | Temperature range(°C) | -35 up to +80 | Weight approx.(kg / km) | 140 |
---|---|---|---|---|---|
Cop | 58 |
KOAX RG 174 A/U
Finished outer diameter(mm) | 2.8 | Temperature range(°C) | -35°C to +80°C | Test voltage(kV) | 2.0 |
---|---|---|---|---|---|
Weight approx.(kg / km) | 11 | Cop | 4.8 |
KOAX RG 178 B/U
Finished outer diameter(mm) | 1.8 | Temperature range(°C) | -55°C to +200°C | Test voltage(kV) | 2.0 |
---|---|---|---|---|---|
Weight approx.(kg / km) | 8 | Cop | 7 |
KOAX RG 179 B/U
Finished outer diameter(mm) | 2.5 | Temperature range(°C) | -55°C to +200°C | Test voltage(kV) | 2.0 |
---|---|---|---|---|---|
Weight approx.(kg / km) | 16 | Cop | 8 |
KOAX RG 180 B/U
Finished outer diameter(mm) | 3.7 | Temperature range(°C) | -55°C to +200°C | Test voltage(kV) | 2.0 |
---|---|---|---|---|---|
Weight approx.(kg / km) | 28 | Cop | 11 |